Garmin da42-l360 User Manual
Garmin G1000 Cockpit Reference Guide for the DA42-L360
190-01062-01 Rev. A
63
Annunciations & Alerts
Flight
Instruments
EIS
Nav/Com/
XPDR/Audio
AFCS
GPS Nav
Flight
Planning
Pr
ocedur
es
Hazar
d
Avoidance
Additional
Featur
es
Abnormal
Oper
ation
Annun/
Alerts
Appendix
Index
gmA 1347 messAge ADvisOries
Message
Comments
GMA1 FAIL – GMA1 is inoperative. The audio panel self-test has detected a failure.
The audio panel is unavailable. The G1000
system should be serviced.
system should be serviced.
GMA1 CONFIG – GMA1 config
error. Config service req’d.
error. Config service req’d.
The audio panel configuration settings do not
match backup configuration memory. The
G1000 system should be serviced.
match backup configuration memory. The
G1000 system should be serviced.
MANIFEST
– GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed. The
G1000 system should be serviced.
G1000 system should be serviced.
GMA1 SERVICE
– GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem in
the unit. Certain audio functions may still be avail-
able, and the audio panel may still be usable. The
G1000 system should be serviced when possible.
the unit. Certain audio functions may still be avail-
able, and the audio panel may still be usable. The
G1000 system should be serviced when possible.
giA 63 messAge ADvisOries
message
Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do
not match backup configuration memory. The
G1000 system should be serviced.
not match backup configuration memory. The
G1000 system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio
configuration. The G1000 system should be
serviced.
configuration. The G1000 system should be
serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING
– GIA2 temperature
too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the G1000 system should be
serviced.
If problem persists, the G1000 system should be
serviced.
GIA2 COOLING
– GIA2 over
temperature.