Seventeam ST-650Z-AF Leaflet

Page of 1
                                                                                ST-650Z-AF
 
Ver. 1.0 
  INPUT CHARACTERISTICS: 
  VOLTAGE: 100VAC ~ 240
 
VAC 
  FREQUENCY: 50
 
~60
 
HZ 
  INPUT CURRENT:
 
10~6 A (RMS)   
  INRUSH CURRENT: 160A MAX 
                                                       
 
  SPECIFICATION: 
  EFFICIENCY: 80% MAXIMUM, FULL LOAD CONDITION AT 230 VAC INPUT. 
  POWER GOOD SIGNAL: ON DELAY TIME 100 ~ 500 ms, OFF DELAY TIME 1ms. 
  HOLD UP TIME: 14ms AT 25℃  80% LOAD CONDITION AT 115-230 VAC INPUT. 
  OPERATING TEMPERATURE RANGE: 5℃ ~ 50℃. 
  REMOTE ON/OFF CONTROL: THE POWER SUPPLY OUTPUT SHALL BE ENABLED WITH AN 
ACTIVE-LOW TTL SIGNAL. WHEN TTL SIGNAL IS LOW, THE DC OUTPUTS ARE TO BE ENABLED. 
WHEN TTL SIGNAL IS HIGH OR OPEN CIRCUITED, THE DC OUTPUTS ARE TO BE DISABLED. 
  OVER POWER PROTECTION: AT 230 VAC INPUT THE POWER SUPPLY WILL SHUT DOWN ALL 
DC OUTPUT WITH IN 110% TO 140% OF FULL LOAD. 
  OVER VOLTAGE PROTECTION: +5V → 7.5V, +12V → 16.5V, +3.3V → 4.8V. 
  EMI REQUIREMENT: FCC PART 15 SUBPART B, CLASS B AT SYSTEM LOAD, CISPR 22 CLASS B. 
  SAFETY: TUV,CUL, CE,CB, FCC,BSMI 
  DIMENSION: 160 (D) x 150 (W) x 86 (H) mm. 
  COOLING: ONE 120mm DC FAN. 
  ACTIVE POWER FACTOR CORRECTION: EN 61000-3-2: 1995+A1+A2: 1998, CLASS D. 
 
 
  OUTPUT CHARACTERISTICS: 
OUTPUT CURRENT 
REGULATION 
OUTPUT 
OUTPUT 
VOLTAGE 
MIN 
[A] 
MAX 
[A] 
LOAD 
LINE 
RIPPLE 
MAX 
[P-P] 
NOISE 
MAX 
[P-P] 
+12V1 
1.0 
20 
±5%
 
±1%
 
120mV 
120mV 
+12V2 
1.0 
30 
±5%
 
±1%
 
120mV 
120mV 
+5V 
1.0 
30 
±5% 
±1%
 
50mV 
50mV 
+3.3V 
1.0 
25 
±5%
 
±1%
 
50mV 
50mV 
-12V 
0.8 
±10%
 
±1%
 
120mV 
120mV 
+5VSB 
0.1 
2.5 
±5%
 
±1%
 
50mV 
50mV 
1. MAXIMUM CONTINUOUS COMBINED LOAD ON +5V AND +3.3V OUTPUTS SHALL NOT EXCEED 150W. 
2.  MAXIMUM CONTINUOUS COMBINED LOAD ON +5V, +3.3V AND +12V OUTPUTS SHALL NOT EXCEED 
630 W. 
3. MAXIMUM CONTINUOUS TOTAL DC OUTPUT POWER SHALL NOT EXCEED 650W.