IPSO chm2097n User Manual

Page of 75
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
14
5-08-51
Electrical Installation Requirements - Model IWF025 (2-speed)
Only trained personnel should perform this 
procedure. Use caution while servicing 
machines with covers removed and power 
applied.
W700
WARNING
Boiler Fed/Steam Heat
Electric Heat
Co
de
Vo
lta
g
e
Cy
cl
e
Phase
Wir
e
Full Lo
ad
Amp
s
Recommended 
Circu
it Br
eak
er
(U
S-mar
ket
)
AW
G
/m
m
2
kW S
ta
nda
rd 
Heat
ing Ele
m
ent
s
Full Lo
ad
Amp
s
Recommended 
Circu
it Br
eak
er 
(U
S-mar
ket
)
AW
G
/m
m
2
US NON-US
US
NON-US
N 440-480
50/60
3
3+PE
1
10
6
14/2.5
3x3 kW
N/A
N/A
N/A
N/A
P
380-415
50/60
3
3+N+PE
1
10
6
14/2.5
17.3
25
20
14/2.5
Q 200-240
50/60
3
3+PE
2.5
10
6
14/2.5
27.1
30
25
14/2.5
X 200-240
50/60
1/3
2/3+PE
2.5
10
6
14/2.5
N/A
N/A
N/A
N/A
Alternative Electric Heat Options
N 440-480
50/60
3
3+PE
3x1.4 kW
N/A
N/A
N/A
N/A
P
380-415
50/60
3
3+N+PE
8.6
10
10
14/2.5
Q 200-240
50/60
3
3+PE
14
15
16
14/2.5
X 200-240
50/60
1/3
2/3+PE
N/A
N/A
N/A
N/A
N 440-480
50/60
3
3+PE
3x2 kW
N/A
N/A
N/A
N/A
P
380-415
50/60
3
3+N+PE
11.9
15
16
14/2.5
Q 200-240
50/60
3
3+PE
18.9
25
20
14/2.5
X 200-240
50/60
1/3
2/3+PE
N/A
N/A
N/A
N/A
N 440-480
50/60
3
3+PE
3x4 kW
19.8
25
20
14/2.5
P
380-415
50/60
3
3+N+PE
22.8
30
25
14/2.5
Q 200-240
50/60
3
3+PE
N/A
N/A
N/A
N/A
X 200-240
50/60
1/3
2/3+PE
N/A
N/A
N/A
N/A
Table 3