What’s in the Box? 
In-LineLinc Relay 
Quick Start Guide 
Six (6) wire nuts 
Preparing to Install In-LineLinc 
CAUTIONS AND WARNINGS 
Read and understand these instructions before installing and retain them for future reference. 
This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or 
the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for 
use on power lines other than 120V 60Hz, single phase. Attempting to use this product on non-approved power lines may have 
hazardous consequences. 
Recommended installation practices: 
Use only indoors or in an outdoor rated box. 
Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into. 
Installing this product with the power on will expose you to dangerous voltages. 
Connect using only copper or copper-clad wire. 
This product may feel warm during operation. The amount of heat generated is within approved limits and poses no 
hazards. To minimize heat buildup, ensure the area surrounding the rear of this product is as clear of clutter as possible. 
Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label. 
To reduce the risk of overheating and possible damage to other equipment, do not use this product to control Loads in 
excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s 
specifications. If this device supports dimming, please note that dimming an inductive Load, such as a fan or transformer, 
could cause damage to the dimmer, the load-bearing device or both. If the manufacturer of the load device does not 
recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH 
DIMMING AN INDUCTIVE LOAD. 
Identifying the Electrical Wires in Your Home 
Line – carries 120VAC electricity into the wall box, may also be called hot, live or power, commonly black 
Neutral – returns 120VAC to power company, commonly white and in a multi-wire bundle 
Load – connects to light/load device, commonly black and in a separate cable jacket  
Ground – connection to electrical ground, commonly a bare wire, a green wire or a screw on a metal box 
 
IMPORTANT! 
If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about and comfortable with electrical 
circuitry, have a qualified electrician install the product for you.
 
Tools Needed 
Non-conductive probe 
 
 
-     Phillips screwdriver 
Wire cutter/stripper  
 
 
-     Voltage meter 
 
Installing In-LineLinc 
1) 
If you plan to configure In-LineLinc using home-management software (such as HouseLinc) or  
SmartLinc (2412N), write down the INSTEON I.D. and the fixture in which it’s being installed for 
future reference. 
2) 
Turn off the circuit breaker/fuse panel supplying power to the fixture. Check that the power is off 
by toggling the load on and off from its local switch. 
3) 
Remove wallpaper from the fixture, unscrew it and remove from the junction box. 
4) 
Disconnect wires from fixture. If the wires cannot be detached by unscrewing, cut the wires where 
they enter the switch and strip ½” of insulation off the ends. Make sure the wires are not touching 
anything. 
5) 
Turn on circuit breaker, then use a voltage meter to identify the Line, Load, Neutral and Ground 
wires. Once all wires are identified, turn off circuit breaker again.