In-LineLinc’s status LED will start blinking.
 
3)  Tap In-LineLinc’s Set button until it beeps again. 
 
You will have 4 minutes to complete the next step before multi-linking mode times out. 
4)  One at a time, press and hold each responder’s Set button about 3 seconds. 
5)  After you have linked all responders, tap In-LineLinc’s Set button. 
6)  Confirm that linking was successful by tapping In-LineLinc’s On and Off buttons. 
 
 
All the linked responders will respond appropriately. 
 
Unlinking Multiple Responders from In-LineLinc Relay 
If you are no longer going to use an In-LineLinc Relay that is controlling one or more INSTEON 
responders or you are removing one or more of the responders, it is important that you unlink all of them 
from In-LineLinc. This is an easy way to unlink multiple responders from In-LineLinc at once. 
 
1)  Press and hold In-LineLinc’s Set button until it beeps. 
 
 
In-LineLinc’s status LED will start blinking.
 
2)  Press and hold In-LineLinc’s Set button until it beeps again. 
 
Status LED will continue blinking. 
 
3)  Tap In-LineLinc’s Set button. 
You will have 4 minutes to complete the next step before multi-unlinking mode times out.
 
4)  One at a time, press and hold each responder’s Set button about 3 seconds. If the responder is a 
multi-scene device such as a KeypadLinc, tap the scene button you want to unlink, then press and 
hold the Set button. 
5)  When all the desired responders have been unlinked, tap In-LineLinc’s Set button. 
6)  Confirm that unlinking was successful by tapping In-LineLinc’s On and Off buttons. 
 
 
None of the responders will respond. 
 
Power Restore
 
In-LineLinc Relay stores all of its scenes, properties, etc. in its internal non-volatile memory so all settings 
are retained after a power outage. Upon power being restored, In-LineLinc will return its connected 
load(s) and all LEDs to their states prior to power outage. 
 
Factory Reset 
Factory Reset clears all user settings from In-LineLinc Relay, including INSTEON scenes, on-levels, ramp 
rates, X10 addresses, etc.  
 
1)  Make sure In-LineLinc Relay is unlinked from all controllers. 
2)  Turn off the breaker supplying power to In-LineLinc Relay’s fixture. 
3)  Wait 10 seconds. 
4)  Push in Set button and hold it. While continuing to hold in the Set button, have a partner turn on the 
circuit breaker.
 
5)  Release the Set button.
 
A few seconds will pass, then In-LineLinc will double-beep. 
The connected load will turn on.