Minicom Advanced Systems 116 IP User Manual

Page of 56
SMART 116 IP 
33 
Full Screen Mode - Check this option to make the remote session screen appear in 
full screen mode from the next reconnection onwards. To toggle the full screen 
mode on and off, press F11
Configuration – This only appears in the menu when an Administrator is logged 
in. Click Configuration to access the Web configuration interface. 
23.11 Disconnecting the remote session 
To disconnect the session, on the Toolbar, click 
. The Login page appears. 
You can re-login, or close the browser window to disconnect the session. 
24. Troubleshooting - Safe mode 
From the Safe mode you can: 
Restore factory defaults - When you cannot access the system e.g. you have 
forgotten the Username or Password, restore factory defaults from the Safe mode. 
(Section 
 
21 on page 22 explained how to restore factory settings from the Web 
interface). 
Restore the device firmware – If during a firmware update there is a power 
failure and you can no longer access the system you can restore the device 
firmware from the Safe mode. 
24.1 Entering Safe mode 
To enter Safe mode: 
1.  Press and hold down the Local button for 3-4 seconds and at the same time 
power up the Smart 116 IP. The device boots up in Safe mode. 
2.  Wait until the unit finishes booting (1-2 minutes). 
3.  You need to know the IP address of the Smart 116 IP. The IP address depends 
on whether there is a DHCP server on the network. If there is, the DHCP server 
assigns an IP address to the Smart 116 IP. If there is no DHCP server, the unit 
boots with the static IP address 192.168.2.155.  
  Open Internet Explorer and type the following into the Address box: http://IP 
address/config. (Do not start the address with https). The Login page appears, 
see Figure 29.