2.4 DIP SWITCH SETTINGS
Open the cover of the DIP switches on the bottom 
of the cradle in order to reach the DIP switches. 
• Turn the DIP switch ON by moving it upwards.
• Turn the DIP switch OFF by moving it downwards.
Single cradle DIP switch settings:
Multicradle DIP switch settings:
* Set baud rate as in table below.
** In typical use keep cascade switch SW5 off.
User baud rate settings:
DIP 
Switch
ON
OFF
SW 1
Baud rate *
Baud rate *
SW 2
Baud rate *
Baud rate *
SW 3
Baud rate *
Baud rate *
SW 4
Spare
SW 5
Spare
SW 6
Auto-baud 
rate (PC-
controlled)
SW 1, 2, 3 
determines 
baud rate.
DIP 
Switch
ON
OFF
SW 1
Baud rate *
Baud rate *
SW 2
Baud rate *
Baud rate *
SW 3
Baud rate *
Baud rate *
SW 4
RS232/
RS485
RS232 only
SW 5
Cascade **
SW 6
RS485 
termination 
ON
RS485 
Termination 
OFF
SW 7
Factory 
setting
SW 8
Factory 
setting
*) Baud rate
SW
1
SW
2
SW
3
2400
ON
OFF
OFF
4800
OFF
ON
OFF
9600 (default)
ON
ON
OFF
19200
OFF
OFF
ON
38400
ON
OFF
ON
57600
OFF
ON
ON
115200
ON
ON
ON