ICOM IC-706MKIIG User Manual

Page of 75
44
5
MEMORY AND SCAN OPERATION
Select VFO mode, then set a frequency.
Close the squelch with [SQL].
Set the desired memory channel as the watching
channel.
Select S2, then push [
(F-2)
PRI] to start the watch.
• Decimal point blinks while scanning.
When the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
To cancel the scan push [
(F-2)
PRI].
N
No
otte
e:: The paused condition when detecting a signal
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.
Select memory mode.
Close the squelch with [SQL].
Select S2, then push [
(F-1)
SCN] to start the mem-
ory scan.
• Decimal point blinks while scanning.
Push [
(F-2)
SEL] to change the memory scan to
select memory scan.
• Push [
(F-2)
SEL] for 2 sec. to clear all select memory
channels.
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
To cancel the scan push [
(F-1)
SCN].
N
No
otte
e:: Two or more memory channels must be desig-
nated as select memory channels for select memory
scan to start.
S2 SCN SEL V/M
Select
memory mode
Designate
“S.”
F-1
F-2
Push [
(F-1)
SCN], then [
(F-2)
SEL].
CH
S
MEMO
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
Select memory mode.
Close the squelch with [SQL].
Select S2, then push [
(F-1)
SCN] to start the scan.
• Decimal point blinks while scanning.
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
To cancel the scan push [
(F-1)
SCN].
N
No
otte
e:: Two or more memory channels must be pro-
grammed for memory scan to start.
S2 SCN SEL V/M
Select
memory mode
F-1
then push [
(F-1)
SCN]
CH
MEMO
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
Select VFO mode.
Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
Set [SQL] open or closed.
• See page a left for squelch condition.
Select S2, then push [
(F-1)
SCN] to start the scan.
• Decimal point blinks while scanning.
When the scan detects a signal, the scan turns
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.
• During scan [TS] can be used only when resume is ON.
To cancel the scan push [
(F-1)
SCN].
N
No
otte
e:: If the same frequencies are programmed into
the scan edge memory channels 1A and 1B, pro-
grammed scan does not start.
■ P
Prro
og
grra
am
mm
me
ed
d s
sc
ca
an
n o
op
pe
erra
attiio
on
n
■ M
Me
em
mo
orry
y s
sc
ca
an
n o
op
pe
erra
attiio
on
n
■ S
Se
elle
ec
ctt m
me
em
mo
orry
y s
sc
ca
an
n o
op
pe
erra
attiio
on
n
S2 SCN PRI V/M
Select
VFO mode
Select watching
channel
F-2
Push [
(F-2)
PRI].
CH
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
VFO A
■ P
Prriio
orriitty
y w
wa
attc
ch
h
CH
VFO A
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
S2 SCN PRI V/M
Select
VFO mode
F-1
then push [
(F-1)
SCN]
IC-706MKIIG.qxd  02.3.27 13:53  Page 44