NOTE: When DC braking is performed, the inverter automatically holds the carrier 
frequency at 1 kHz.
NOTE: The carrier frequency setting must stay within specified limits for inverter-
motor applications that must comply with particular regulatory agencies. For example, a 
European CE-approved application requires the inverter carrier to be less than 5 kHz.
B_84, B_85: Initialization codes – These functions allow you to restore the factory 
default settings. Please refer to 
B_86: Frequency display scaling – You can convert the output frequency monitor on 
D_01 to a scaled number (engineering units) monitored at function D_07. For example, 
the motor may run a conveyor that is monitored in feet per minute. Use this formula:
 
Scaled output frequency (D_07)
Output frequency (D_01) Factor (B_86)
×
=
“B” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE 
(CE)
–FU 
(UL)
–FR 
(Jpn)
Units
B_32 Reactive current setting
Calibrate detection of motor’s 
no load (reactive) current to 
improve D_02 display 
accuracy, range is 0 to 32 
Amperes
58% rated current
A
IO 0.00A
B_81 [FM] terminal analog 
meter adjustment
Adjust 8-bit gain to analog 
meter connected to terminal 
[FM], range is 0 to 255
80
80
80
ADJ          080
B_82 Start frequency adjust-
ment
Sets the starting frequency for 
the inverter output, range is 0.5 
to 9.9 Hz
0.5
0.5
0.5
Hz
Fmin       0.5Hz
B_83 Carrier frequency 
setting
Sets the PWM carrier (internal 
switching frequency), range is 
0.5 to 16.0 kHz
5.0
5.0
12.0
kHz
CARRIER  05.0kHz
B_84 Initialization mode 
(parameters or trip 
history)
Select the type of initialization 
to occur, two option codes:
00 ...Trip history clear
01 ...Parameter initialization
00
00
00
INIT MODE    TRP
B_85 Country code for initial-
ization
Select default parameter values 
for country on initialization, 
four options, option codes:
00 ...Japan version
01 ...Europe version
02 ...US version
03 ...reserved (do not set)
01
02
00
INIT SEL     USA