Adding Devices and IP Table Setup in SIMPL Windows 
To add Ethernet devices to your program, in the SIMPL Windows' Configuration 
Manager, drag an Ethernet-connected device, e.g. a CEN-IO or a Virtual Touchpanel 
symbol, into the program. Drop it onto the CNXENET+ card or the "Ethernet Units" 
arrow underneath the "Cresnet Units" arrow. (If the "Cresnet Units" arrow is not 
visible in the System View window, pull the window divider down further.)  
1.  Double click on the icon and set an IP ID and a corresponding IP 
address in the tabbed configuration dialog titled "IP Net Address".  
2.  For example, drop a CEN-IO and set it IP ID: 03 at IP address 
192.168.2.7 OR in the SIMPL Windows Program Manager, connect 
signals to the "Virtual Touchpanel" symbol, exactly as you would to a 
regular wired Touchpanel symbol. 
NOTE:  For more detailed information, refer to the SIMPL Windows help file by 
selecting Help | Help Topics. Select the Index tab, type in IP Table, then select 
Adding Ethernet Devices to a SIMPL Windows Program
When the SIMPL Windows program is compiled, the compiler creates an IP table 
consisting of the IP IDs and the IP addresses that were entered for the various 
Ethernet devices added to the program. During upload, choose whether to load this 
IP table or whether to use the table that already exists in the control system. 
Changing the IP Table via Crestron Viewport 
You can modify the corresponding IP address for any IP ID without changing or 
reloading the program by changing the IP table directly. From the Crestron Viewport 
select Functions | Setup IP Table then click the Retrieve Current IP Table from 
Control System
 button. This will extract the IP table from the control system and 
list it in the dialog box. Modify or delete existing entries or add new ones and save 
the new table to disk and/or load it back into the control system. Do not overwrite the 
IP table in the control system the next time the program is uploaded, unless the 
addresses in the program supercede those in the current IP table. 
NOTE:  For more detailed information, refer to the SIMPL Windows help file by 
selecting Help | Help Topics. Select the Index tab, type in IP table, then select 
Changing IP Addresses without Changing the Program
Crestron e-Control IP Table Information 
It is extremely important that the IP ID in the SIMPL Windows program match the 
IP ID (sometimes called the Cres ID) encoded in the Crestron e-Control SDK object 
by the developer of the Web page or Visual Basic® program.  
If more than one PC uses the same IP ID for a connection (e.g. each loads the same 
Web page), the CNX Gateway will duplicate all packets that are received from the 
control system to each of the identical IP IDs. This is known as touchpanel tracking. 
The IP address that is typed into the virtual touchpanel devices in the SIMPL 
Windows program is the IP address of the CNX Gateway, not of the individual PCs 
(running a web browser or Active CNX application). This is because individual 
computers may change, but the CNX Gateway does not.  