Chamberlain WD962KPEV User Manual

Page of 48
26
Option B
2.1B  
Cut the end of the safety 
reversing sensor wire, making 
sure there is enough wire to 
reach the pre-installed wires 
from the wall.
2.3B  
Connect the pre-installed wires to the sensor wires with wire nuts making sure the 
colors correspond for each sensor. For example, the white wire would connect to 
the yellow wire and the white/black wire would connect to the purple wire.
2.2B  
Separate the safety reversing sensor 
wires and strip 7/16 inch (11 mm) 
of insulation from each end. Choose 
two of the pre-installed wires and 
strip 7/16 inch (11 mm) of insulation 
from each end. Make sure that you 
choose the same color pre-installed 
wires for each sensor.
7/16" 
(11 mm)
7/16" 
(11 mm)
Safety reversing sensor wires
Pre-installed 
wires
Safety sensor wires
White
White/Black
Yellow 
(for example)
Purple 
(for example)
2.4B  
At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end of 
the wires previously chosen for the safety reversing sensors. Twist the like-colored 
wires together.
2.5B  
Insert the wires connected to the white safety sensor wires to the white terminal 
on the garage door opener. Insert the wires that are connected to the white/black 
safety sensor wires to the grey terminal on the garage door opener. 
Not Provided
7/16" 
(11 mm)
Yellow
Purple
RED
WHITE
WHITE
GREY
WHITE
WHITE
ED
RED
RED
RE
WH
WHIT
Purple (for example)
Yellow (for example)
To insert or remove the wires 
from the terminal, push in the 
tab with a screwdriver tip.
Pre-installed 
wires
Install the Protector System
®
PRE-WIRED INSTALLATION