blue-seal e1100 User Manual

Page of 41
-23- 
Revision 4/F3591 
© Moffat Ltd, August 2004 
6.3  REPLACEMENT 
6.3.1  POWER / ROAST SWITCHES 
6.2.6 CONTROL PANEL—REAR 
1)  Open the control panel (refer 6.2.1). 
2) Disconnect  the  wires  from  the  faulty 
switch.   
3)  Press in the locking tabs at top and bottom 
of the switch and from rear push switch 
through front of control panel. 
6.3.2  LIGHTS / WATER SWITCHES 
1)  Open the control panel (refer 6.2.1). 
2) Disconnect  the  wires  from  the  faulty 
switch.   
3)  Press in the locking tabs at top and bottom 
of the switch and from rear push switch 
through front of control panel. 
6.3.3  TIME UP / ROAST INDICATORS 
1)  Open the control panel (refer 6.2.1). 
2) Disconnect  the  wires  from  the  faulty  
indicator.   
Figure 6.2.6 
4)  Replace and reassemble in reverse order. 
4)  Replace and reassemble in reverse order. 
Figure 6.3.1 
Locking 
tabs 
Figure 6.3.2 
Locking 
tabs 
Power Switch 
Power Indicator 
Thermostat 
Heating Indicator 
60 Minute Timer 
Time Up Indicator 
Hold Indicator 
3 Hour Timer 
Roast Switch 
Lights Switch 
Water Switch