4.) Enter your tabulated values into the LSR6328P RMC equalizer using the table below:
Data Entry in RMC Equalizer Table:
Control Position
Width (%)
Frequency (Hz)
Depth (dB)
0 (CCW)
4.5
24
0.0
1
5.0
25
0.0
2
7.5
26
0.0
3
10.0
28
0.5
4
12.5
31
1.1
5
16.5
35
1.9
6
20.5
41
2.9
7
23.0
45
4.4
8
26.0
47
6.4
9
28.0
50
7.9
10
29.5
53
8.3
11
31.0
57
8.9
12
34.0
62
9.5
13
39.0
68
10.2
14
41.5
76
11.0
15
43.5
85
11.7
16
45.0
90
12.7
17
46.5
90
13.1
18
48.0
95
13.5
19
49.0
95
13.9
20 (CW)
50.0
95
14
(CCW) counter-clockwise
(CW) clockwise
Begin with the three controls in their far left (CCW) counterclockwise position and adjust
each one, a click at a time, until you have reached the values entered at the bottom of
your measurement chart. See Figure 11.
Making these entries requires carefully counting the clicks. If you make a mistake, or have
lost count, turn the control to the full counter-clockwise position and start over.
Rechecking the system: After you have made the equalizer entries it is time to re-measure
the system, using Tracks 4 through 26 just as you did when making your first sequence of
measurements. Turn on the LSR6328P RMC function by engaging the ENABLE switch, the
green LED will illuminate. Perform the same calibration procedure for the other speakers
in the system. Use the RMC Remote Bypass control to compare before and after settings.
At this point you may make any fine adjustments by ear. When you are satisfied with your
settings, the RMC Remote Bypass Switch can be disconnected from all loudspeakers.
 