Xantech PA435X User Manual

Page of 20
Model PA435X 
 
Page 15 
 
© 2003 Xantech Corporation 
TROUBLE SHOOTING 
 
If you encounter a problem, please review the items in the following list.  Be sure, in addition, to check other system 
components, such as preamplifiers, CD players, speakers, speaker wiring, etc., that may be at fault. 
 
PROBLEM 
PROBABLE CAUSE AND SOLUTION 
Rear panel Power Indicator does not light – no sound. 
Check line cord for good contact in a live AC outlet.  If 
REMOTE CI jacks are being used, be sure applied 
voltage is between +5V and +30V DC with proper 
polarity.  See Fig. 8. 
No sound from CH2, CH4 when stereo operation is 
desired. 
BRIDGED/STEREO switch is incorrectly set to 
BRIDGED position.  Set to STEREO position.   See 
Fig. 6. 
Sound cuts in and out every 3 to 5 seconds. 
Speaker load impedance is less than 4-Ohms for 
Stereo mode or less than 8-Ohms for Bridged mode.  
Make changes in speakers as necessary to obtain 
higher impedance. 
PA435X does not turn OFF when both REMOTE input 
voltages go to 0 Volts. The Logo stays illuminated. 
Be sure that the Front Panel POWER switch (item 2, 
Fig. 2) is set to the REMOTE ON/OFF (OUT) position. 
PA435X becomes very warm, shuts OFF, but does not 
come back ON automatically. 
Set POWER switch (item 3, Fig. 2) to MANUAL OFF 
(OUT) position for 15 seconds, then back ON.  If 
REMOTE ON/OFF jack is used, unplug for 15 seconds, 
then re-plug. 
One or more front panel LED’s glow red. 
The amplifier has been driven into clipping and/or is 
overheating.  Correct faulty condition.