5.  TECHNICAL DATA FOR INSTALLATION 
V08 ENT
M
V08 ENT
M11
V08 ENT
M12
Engine intake and ventilation air when underway
Static vacuum allowed downstream of the air filter  
kPa
mmH
2
O
≤ 3.5
≤ 350
≤ 3.5
≤ 350
≤ 3.5
≤ 350
Engine air intake flow rate
m
3
/h
≥ 3050
≥ -
≥ 4000
Engine room ventilation air flow rate (excluding
 
engine air intake) 
m
3
/h
≥ 7950
≥ -
≥ 6600
Static vacuum allowed in the engine room
kPa
mmH
2
O
≤ 0.1
≤ 10
≤ 0.1
≤ 10
≤ 0.1
≤ 10
Temperature allowed in the engine room
°C
≤ 45
≤ -
≤ 40
Maximum engine room temperature exceed outside temperature
°C
≤ 15
≤ 15
≤ 15
Exhaust gas outlet
Allowed static back pressure
kPa
mmH
2
O
≤ 10
≤ 1000
≤ 10
≤ 1000
≤ 10
≤ 1000
Temperature at maximum power (turbocharger inlet)
°C
510 ± 25  
-
660 ± 25  
Flow rate at maximum power
kg/h
3550
-
4800
Riser outer diameter
mm
inches
-
-
-
-
-
-
Dry exhaust outer diameter
mm
inches
105
4
105
4
105
4
Diameter of circumference of distance between 6 locking holes
mm
inches
127
5
127
5
127
5
Fuel supply
Low pressure pump delivery at maximum rpm
l/h
400
400
400
Fuel temperature to allow maximum power
°C
≤ 70
≤ 70
≤ 70
Inner diameter, intake pipe
mm
≥ 14
≥ 14
≥ 14
Inner diameter, return pipe
mm
≥ 8
≥ 8
≥ 8
Thread on prefilter fittings
M
14 x 1.5
14 x 1.5
14 x 1.5
Thread on engine fittings
inches
 
UIC
1/2
1/2
1/2
Allowed intake vacuum
kPa
mmH
2
O
≤ 50
≤ 5000
≤ 50
≤ 5000
≤ 50
≤ 5000
Allowed intake pressure
kPa
mmH
2
O
≤ 20
≤ 2000
≤ 20
≤ 2000
≤ 20
≤ 2000
Open sea water cooling line
Intake pipe outer diameter
mm
inches 
101
4
101
4
101
4
Pump delivery at maximum rpm
l/h
61000
-
78000
Allowed intake vacuum
kPa
mmH
2
O
≤ 20
≤ 2000
≤ 20
≤ 2000
≤ 20
≤ 2000
Discharge pipeline outer diameter from air/water heat exchanger
mm
inches
51
2
51
2
51
2
Discharge pipeline diameter outer from water/water heat exchanger
mm
inches
89
89
89