INSTALLATION DIRECTIVE
MAY 2006
2
V08 EnT M75 - M11 - M12 
12. CUSTOMIZED INSTRUMENT PANEL
Using only the components of the panel that are not wired 
to allow the panel customization, they will have to be wired 
using the 10 metre long wire harness, set up at one end for 
coupling to the JB connector and at the opposite end with 
conductors  with  free  terminals  with  identifying  numbering 
on each wire. The conductors will have to be connected to 
the individual components as indicated in the electrical and 
wiring diagrams in Chapter 20.
CAUTION
To assure the functionality of the safeties pertaining to the 
engine start/stop commands from the instrument panel or 
engine room, it is mandatory to wire the key switch strictly 
as shown in the electrical diagrams in Chapter 20.
The  wiring  details  of  the  indications  and  alarms  module
alone are provided below; indications for IVECO MOTORS
indicator  instruments  are  shown  in  the  related  wiring  dia-
grams in Chapter 20.
JD Connector for indications and alarms 
module
VIEW FROM THE SIDE InTEGRATED In THE REAR PART 
OF THE MODULE
Figure 
VIEW FROM THE TERMInAL SIDE OF THE COUPLInG 
SIDE WIRInG
connector
TRIDEnT / ITT CAnnOn  part TST 24PA00
terminal
female
part 192990-0050
lid
rear
part  TST24AH0
JD connects the indications and alarms module to the elec-
trical system of the engine (sensors, power supply, etc.).
The  terminal  part  of  the  wire  harness,  supplied  with  the 
module,  must  be  completed  using  female  terminals,  as 
described in the electrical diagram of Chapter 20.
For standard-equipped engines, to have the essential indica-
tions available, the following ways must be wired: 1, 3, 7, 8, 
9, 10, 11, 13, 14, 15, 16, 17, 18, 19 with the female terminals 
supplied as standard equipment.
Figure 
13
9
5
1
14 15 16
10 11 12
6
2
4
7
8
3
21 22 23 24
17 18 19 20
04_241_n
1
2
3
4
5
6
8
7
10 9
12 11
13
14
16 15
17
18
20 19
21
22
24 23
05_034_C