Crestron eServer™
 
device, a unique IP address, subnet mask, default router, and IP table settings must 
be defined. These settings among others can be defined using setup menus. A future 
release of the Crestron Viewport will provide integrated tool support.  
The eServer setup menus can be accessed only after connecting the communications 
port of the PC to the COM IN port on the eServer. A serial cable is provided in the 
dealer kit. After connecting the eServer and before applying power to it, open the 
communications package that resides on the PC. Viewport from either SIMPL 
Windows or VisionTools Pro-e is used in the illustrations that follow. Be sure to set 
the PC communication parameters (Alt+D) as shown after this paragraph. No 
handshaking is required (do not check the XON/XOFF or RTS/CTS check boxes).  
“Port Settings” Dialog Box – as viewed after entering Alt+D 
 
NOTE:  If XON/XOFF is checked, communication with the device may be 
unreliable.  
Apply power to the eServer and notice that the Viewport window changes as 
communication is established with the eServer, shown after this paragraph. 
12  
  Ethernet OEM Module: eServer™ 