Crestron cen-oem User Manual

Page of 44
Ethernet OEM Module 
 
Crestron eServer™
 
Sample Response to the “port” Command 
 
As noted in the description column in the Main Menu, a typical port command has 
the following format: 
port device[,baud][,N81][,option ON:OFF] 
The command is not case sensitive. Parts of the command enclosed by brackets ([ ]) 
are optional and need not be entered unless a change is necessary. There are several 
port options that can satisfy the [option] [ON:OFF] part of the command. To view 
the options enter the following: 
port ? 
Sample Response to the “port ?” Command 
 
Options for the "port" command are listed in the left-most column. Possible settings 
for each of the options are listed in the right-most column. Only the options for the 
DEVICE port can be changed. For example, to turn on hardware handshaking for the 
DEVICE port, enter the following command: 
port device,h/w on 
Sample Response to the “port device,h/w on” Command 
 
Once the above command is entered, the new settings are saved to non-volatile 
memory. Invalid baud rates, comspecs, or options are ignored. A brief description of 
valid baud rates, comspecs, and options is shown after this paragraph.  
16  
  Ethernet OEM Module: eServer™ 
Operations Guide - DOC. 8148