Appendix C: Uploading a SIMPL+ Program 
Use the Viewport to upload a SIMPL+ program to the CEN-OEM. Connect the 
COM IN port of the eServer to the desired COM port of the PC. Verify 
communication parameters and be sure the eServer power pack is connected and 
supplying power to the device.  
Depress ENTER on the keyboard. If the Viewport responds with ">", 
communications is verified.  
From Viewport, select File Transport | Send SIMPL+ Program to the  
CEN-OEM
.  
Crestron Viewport 
 
The "Open" dialog box appears. Browse for the desired .csz file and select OK. The 
file is transferred to the eServer.  
Operations Guide - DOC. 8148 
Ethernet OEM Module: eServer™  