Fagor nc-200 pb Installation Instruction

Page of 58
Page: 14 - Installation Manual - NC-200 PB
2.2 INPUT/OUTPUT CHARACTERISTICS (X2)
A 37-pin female connector is used.
Signal characteristics of connector "X2":
The supply voltage is at +24V (±25%), thus the threshold
between a "0" and a "1" will be about +6V.
Characteristics of the inputs at 24V :
- Maximum load current:  100mA
- Minimum DC voltage:   18V
- Maximum DC voltage:  30V
The main characteristics of the digital outputs are:
(optocoupled with solid state relay with a normally open
contact)
- Maximum AC or DC voltage:
48V
- Maximum load current:
150 mA
- Maximum internal resistance:
24Ohm
- Maximum peak current:
500mA for 100ms
at 25ºC
- Through current when open:
 1µA
- Leak current:
200nA (Vload=100V)
- Galvanic isolation voltage:
1500V for 1 minute
- Activation time:
 3ms
- Deactivation time:
 3ms
Main characteristics of the analog outputs
Voltage range:
±10V
Resolution: 4.88mV
Maximum current: 10mA
Offset:
±30mV
Impedance:
120 Ohm referred to GND