Nautilus t516 User Manual

Page of 46
10
 
1.0 - rEPLACEMENT oF CroWNED FroNT roLLEr
Tools Needed: 
• Phillips Screwdriver
• 3/16 inch Hex Key / Allen Wrench
• 1/2 inch wrench 
• 7/16 inch wrench
NOTE:Ifusingapowereddriver,itmustbeonthe
“LOWTORQUE”setting,otherwiseitwill
stripscrews.
1-1    Elevate the treadmill, secure power and then 
unplug the power cord from the wall outlet.
1-2  Remove (4) Phillips head screws with a Phillips 
screwdriver from the inside, lower right upright 
plastic cover and (4) Phillips head screws from 
the outer right side plastic cover. Remove the right 
side outer plastic cover (Figure 1). Repeat process 
on the left side.  
1-3 Remove the motor cover (Figure 2 & 2A).
1-4  Release the tension from the walking belt by 
loosening the rear roller bolts using the 3/16 inch 
Hex Key/Allen wrench provided with the treadmill. 
Turn the rear roller bolts counter clockwise to 
release tension.
1-5  With a 3/16 inch hex key, remove the front roller 
bolt located on the left hand side of the treadmill 
(Figure 4).
 mechanical Service guide 
Figure 1: 
Figure 2: 
Figure 2-A: 
7 ! 2 . ) . '
! 4 4 % . 4 ) / .
$ ! . ' % 2
)--%$)!4%
# ! 5 4 ) / .
AS LoNG AS ThE TrEADMILL IS PLuGGED INTo A 
PoWErED ouTLET AND ThE TrEADMILL CIrCuIT 
BrEAKEr IS oN, ThE uNIT IS rECEIVING PoWEr, 
EVEN IF ThE DISPLAY IS TurNED oFF. ALWAYS 
uNPLuG ThE PoWEr CorD FroM ThE ouTLET 
AND TrEADMILL WhEN PErForMING rEPAIrS or 
MAINTENANCE.