Kodak i800 Series User Manual

Page of 123
 
A-61510 January 2005 
 4-22 
Setting Multi-feed detection  Multi-feed Detection aids in document processing by detecting 
documents that may go through the feeder overlapped. Multi-feeds can 
happen due to stapled documents, adhesives on documents, or 
electrostatically charged documents. 3D Multi-feed Detection combines 
ultrasonics (amplitude and phase) with physical length detection to 
virtually eliminate the chance of loosing data due to multi-feeds. 
The Ultrasonic Sensor is located in the center of the transport (behind 
the feeder module). In order for multi-feed documents to be detected 
correctly, they must pass under this sensor. 
Length Detection 
 this option can be enabled or disabled. The 
default is disabled. If Length Detection is enabled, enter the maximum 
length (in inches). This is the minimum length of the document that can 
be scanned with a multi-feed being detected. Length detection is used 
when scanning same-sized documents to check for overlap. For 
example, if you are scanning 8 ½ x 11” documents in portrait mode, you 
may want to enter a value of 11.25 in the Maximum Length field. The 
maximum value is 30.5 inches. 
Auto Set 
 when enabled, will automatically set the maximum length 
value to .50-inch greater than the length of the currently selected page 
size. 
Units 
 length detection will be displayed in inches. Pixels and 
Centimeters are not available through the graphical user interface. 
Stop Scanner 
 if this option is not selected, the scanner will display 
and log the condition but continue to operate. If selected, the scanner 
will display, log the condition and stop the feeder (the scanner will 
remain enabled). When an overlap or multi-feed is detected, the 
scanner stops the feeder, clears the transport of all pages and then the 
documents can be refed. 
End Job 
 if this option is selected, the scanner will display, log the 
condition and stop the feeder and transport (the scanner will be 
disabled). Scanning can only be resumed when the scanner is 
re-enabled from the host.