Brother 484C User Manual

Page of 198
8. ELECTRIC MECHANISM 
 
 
Error status    #20    The machine does not stop with the needle at the upper position.   
(“E-50” appears <“E.22” for the KE-436B and 436C>.) 
Probable causes 
Check/ repair/ adjust 
Parts to be replaced 
3. Cord defective 
• See #15-1. 
 
 
 
 
4. Power supply circuit board 
defective 
 
 
 
 
KE-430B, 430C series 
189 
 
 
 
 
 
 
• With P13 (DC18) connectors plugged in 
on the main circuit board, measure the 
voltage in the connector on the cable. 
  If the voltage across the following pairs of 
pins, pins 1 and 2, pins 4 and 5, and pins 
10 and 11 is DC 15–18 V, it is OK. 
 
Power supply circuit 
board 
 
5.  Main circuit board defective 
 
 
 
Main circuit board 
+15 – 18V for each 
Main circuit board 
3651Q 
 
6. Motor defective 
 
 
 
Motor 
 
 
 
Error status    #21    Programming can not be made. (KE-436B, 436C only) 
Probable causes 
Check/ repair/ adjust 
Parts to be replaced 
1. The programmer connector 
and its cable are defective. 
 
• Remove connector P2 (PGM) on the 
panel PCB and connector P2 on the 
programmer PCB, and then return them to 
their positions. 
 
 
2.  The programmer is defective. 
 
•  Replace the programmer with a new one. 
 
Programmer 
 
3.  Panel circuit board defective 
 
•  Replace the panel circuit board with a new 
one. 
 
Panel circuit board