Zebra S400 & S600 User’s Guide
$&3RZHU)XVH5HSODFHPHQW
A user-replaceable AC power fuse (see Figure 6) is located just to the left 
of the power on/off switch.  For use with both voltage ranges, the 
replacement fuse is a 5 x 20 fast blow style rated at 5 Amp/250 VAC.
1. Before replacing the fuse, turn the AC power switch off and unplug 
the AC power cable.
2. To replace the fuse, insert the tip of a flathead screwdriver into the slot 
in the end of the fuse holder end cap.
3. Press in slightly on the end cap and turn the screwdriver slightly 
counterclockwise.  This disengages the end cap from the fuse holder 
and permits the removal of the fuse.
4. To install a new fuse, remove the old fuse and insert the new fuse into 
the fuse holder.
5. Push the end cap in slightly, then insert the tip of a flat blade 
screwdriver into the slot in the end cap and turn clockwise to engage it.
6. Plug in the AC power cable and turn the AC power switch on.
0HFKDQLFDO$GMXVWPHQWV
This printer has been designed so that minimal operator adjustments are 
required.
3ULQW4XDOLW\$GMXVWPHQWV
When changing from one media/ribbon combination to another, only slight 
changes in print darkness or toggle pressure may be required.  For these 
situations, refer to “Toggle Pressure Adjustment” on page 40.