NOTE:  When XON/XOFF handshaking is selected, data flow is 
controlled by the ASCII control codes DC1 (XON) and DC3 
(XOFF).  The DTR control lead has no effect.
,QWHUFRQQHFWLQJWR'7('HYLFHV
The printer is configured as data terminal equipment (DTE).  To connect 
the printer to other DTE devices (such as the serial port of a personal 
computer), use an RS-232 null modem (crossover) cable.  Figure 31 shows 
the required cable connections.
,QWHUFRQQHFWLQJWR'&('HYLFHV
When the printer is connected via its RS-232 interface to data 
communication equipment (DCE) such as a modem, a STANDARD      
RS-232 (straight-through) interface cable must be used.  Figure 32 shows 
the connections required for this cable.
RS-232 Connector Pinouts
Pin. No.
Description
1
Not used
2
RXD (receive data) input to the printer
3
TXD (transmit data) output from the printer
4
DTR (data terminal ready) output from the printer — controls when the host 
may send data
5
Chassis ground
6
DSR (data set ready) input to the printer
7
RTS (request to send) output from the printer — always in the ACTIVE 
condition when the printer is turned on
8
Not used
9
5  V  Fused