ZyXEL Communications P-870HW-I User Manual
P-870HW-I1 User’s Guide
216
Chapter 16 Remote MGMT
The following table gives a description of TR-069 commands.
Table 102 TR-069 Commands
Root
Command or
Subdirectory
Subdirectory
Command
Description
wan
tr069
All TR-069 related commands must be preceded by wan tr069.
load
Start configuring TR-069 on your ZyXEL Device.
active [0:no/
1:yes]
1:yes]
Enable/disable TR-069 operation.
acsUrl <URL>
Set the IP address or domain name of CNM Access.
username
[maxlength:15]
[maxlength:15]
Username used to authenticate the device when making a
connection to CNM Access. This username is set up on the server
and must be provided by the CNM Access administrator.
password
[maxlength:15]
[maxlength:15]
Password used to authenticate the device when making a connection
to CNM Access. This password is set up on the server and must be
provided by the CNM Access administrator.
periodicEnable
[0:Disable/
1:Enable]
[0:Disable/
1:Enable]
Whether or not the device must periodically send information to CNM
Access. It is recommended to set this value to 1 in order for the
ZyXEL Device to send information to CNM Access.
informInterval
[sec]
[sec]
The duration in seconds of the interval for which the device MUST
attempt to connect with CNM Access to send information and check
for configuration updates. Enter a value between 30 and
2147483647 seconds.
save
Save the TR-069 settings to your ZyXEL Device.