Chapter 16 Remote MGMT
The following table gives a description of TR-069 commands. 
Table 102   TR-069 Commands
Root
Command or 
Subdirectory
Command
Description
wan
tr069
All TR-069 related commands must be preceded by wan tr069.
load
Start configuring TR-069 on your ZyXEL Device.
active [0:no/
1:yes]
Enable/disable TR-069 operation. 
acsUrl <URL>
Set the IP address or domain name of CNM Access. 
username 
[maxlength:15]
Username used to authenticate the device when making a 
connection to CNM Access. This username is set up on the server 
and must be provided by the CNM Access administrator.
password 
[maxlength:15]
Password used to authenticate the device when making a connection 
to CNM Access. This password is set up on the server and must be 
provided by the CNM Access administrator.
periodicEnable 
[0:Disable/
1:Enable]
Whether or not the device must periodically send information to CNM 
Access. It is recommended to set this value to 1 in order for the 
ZyXEL Device to send information to CNM Access.
informInterval 
[sec]
The duration in seconds of the interval for which the device MUST 
attempt to connect with CNM Access to send information and check 
for configuration updates. Enter a value between 30 and 
2147483647 seconds. 
save