Kenwood TK-480 User Manual

Page of 55
39
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-480/481
1. Sensitivity
1) SYS – GRP : 1 – 1
SSG
Panel
ANT
Check
12dB SINAD or more.
check
SSG output : –116dBm
MOD : 1kHz
AF VTVM
DEV : 
±
3kHz (TK-480)
Oscilloscope
:
±
1.5kHz (TK-481)
Distortion
meter
2. Squelch
1) SYS – GRP : 4 – ✽
Panel
Encoder Adjust to point of
adjustment
Select
SQL    ✽ ✽ ✽
knob
closing squelch.
in tuning mode.
SSG output : 3dB below to
12dB SINAD level
3. Squelch
1) SYS – GRP : 4 – 1
Check
Squelch must be opened.
check
SSG output : 12dB SINAD level
See Note.
2) SSG output : OFF
Squelch must be closed.
Note : When squelch is adjusted, the microcomputer simultaneously reads and writes the RSSI level. Do not write adjustment values without the SSG
connected.
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
Receiver Section
22. BATT
1) SYS – GRP : 4 – 1
Power meter Panel
ANT
Panel
Encoder Check
Can not transmit.
detection
BATT terminal voltage : 5.7V
Deviation
knob
LED (TX) blinks.
check
PTT : ON
meter
Oscilloscope
2) BATT terminal voltage : 6.5V
Transmit
PTT : ON
AG
AF VTVM
Note : When the CPU is changed these adjustment values will become suitable values for NPSPAC, the deviations except MAX DEV in NPSPAC band
are automatically adjusted.