3.
 
S
ETUP
 
Lamp 
You will need to install a lamp prior to the initial operation of the fixture. A HTI 150W discharge lamp 
is included.  
Warning! 
When replacing the lamp, please wait 15 minutes after powering down to allow the unit to cool 
down! Always disconnect from main power prior to lamp replacement. 
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp 
with alcohol and wipe it with a lint free cloth before installation. 
Maximizing the life of your lamp 
 
Note: To ensure the longest and most efficient use of the lamp always wait between 10 and 15  
minutes before re-applying power after a shutdown.  
 
 
 
Failure to do so could result in premature aging of the lamp and failure to the electronics that drive it.  
Never turn off the power to the unit while the lamp is striking. Always wait 15 minutes after powering 
on the fixture before powering down. Turning off the lamp during striking may permanently damage 
the lamp. 
Lamp Installation 
Follow the instructions below for lamp installation. 
 
1) 
Turn off power to fixture. 
2) 
Loosen the 2 lamp covers knobs by turning counter-clockwise. 
3) 
If there is a current lamp you are replacing, remove it now. 
4) 
While using care not to allow the globe of the lamp to contact your bare skin,  
install the new lamp.  
5) 
Replace lamp cover and tighten knobs. 
 
 
 
 
 
Lamp cover screws