Fujitsu sparc enterprise m8000 User Manual

Page of 444
ioxadm(8)
System Administration
85
NAME
ioxadm - manage External I/O Expansion Units
SYNOPSIS
ioxadm
[-f] [-p] [-v] [-M] env [-e] [-l] [-t] [ target sensors]]
ioxadm
[-f] [-p] [-v] [-M] list [ target]
ioxadm
[-f] [-p] [-v] [-M] locator [on|off] [ target]
ioxadm
[-f] [-p] [-v] [-M] poweroff target
ioxadm
[-f] [-p] [-v] [-M] poweron target
ioxadm
[-f] [-p] [-v] [-M] reset target
ioxadm
[-f] [-p] [-v] [-M] setled [ on|off|slow|fast] target led_type
ioxadm -h
DESCRIPTION
ioxadm
(8) manages External I/O Expansion Units and link cards attached to the
system.
For this utility, an operand with parameters and a target device must both be
specified. The target device can be a downlink card mounted in a built-in PCI slot
in the host system; an External I/O Expansion Unit; or a field replaceable unit
(FRU) in an External I/O Expansion Unit. The downlink card is identified by a
string which identifies the host path to the card. An uplink card is a FRU in the
I/O boat.
Privileges
You must have one of the following privileges to run these commands:
Refer to setprivileges(8) for more information.
OPTIONS
The following options are supported.
Required Privileges
Operands
platop
env
, list
platadm
env
, list, locator, poweroff, poweron
fieldeng
All operands
-f
Forces command execution by ignoring warnings.
-h
Displays usage statement.
When used with other options or operands, an error occurs.