Nortel Networks 5399 User Manual

Page of 126
2-27
Chapter 2
Installing the Model 5399 Remote Access Concentrator Module
Nortel Networks 5399 Access Switch Hardware Installation Guide
Booting Using BFS
Perform the following steps to boot the Remote Access Concentrator
using BFS:
1.
Initialize the IP address parameters using either the
auto-initialize or manual initialize method.
The auto-initialization method is described in
. The manual
initialization method is described in
.
2.
Enter the boot command.
If you do not enter a file name with the command, you are
prompted for one (the default file name is displayed at the
prompt: oper.64.enet). Press
to boot using the default file
name.
The following example shows a typical screen display for a BFS
boot using erpcd on UNIX or Windows NT:
Enter boot file name[oper.64.enet]::
Waiting for CMB Config Block Info...
Requesting boot file ”oper.64.enet”.
Unanswered requests shown as ’?’,transmission errors
as ’*’.
Requesting boot from 192.9.200.88 via Ethernet...
Booting BFS file using open delay of 8
Booting BFS file from 192.9.200.88
Header received OK. Received data blocks shown as ’.’.
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .. . . . . . . . . . . ? . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . * . . . . .
. . . . . . . . . . . . . . . . . . . . . . . * . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . ? . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EOF
Enter