Nortel Networks 5399 Access Switch Hardware Installation Guide
Chapter 4
Troubleshooting Procedures
4-4
Table 4-1. Model 5399 Front Panel LEDs (continued)
During power-up and booting, it is more difficult to diagnose problems
because they can originate in the Remote Access Concentrator, the
Ethernet, or the load server host. However, the LEDs provide both a
progress report and an error display to assist you in troubleshooting.
If an error occurs, save the status of these LEDs. Technical
support personnel can use this information to diagnose
problems.
Power-up and Boot Procedures
The Remote Access Concentrator has two modes of operation: Normal
Mode and Monitor Mode. Normal Mode is the standard operational mode.
Monitor Mode is a diagnostic mode that provides access to the ROM
Monitor commands.
During its power-up and boot sequence, the Remote Access
Concentrator runs a set of diagnostics. The system LEDs display the
diagnostics’ status. The pattern of the system LEDs identifies the error
condition.
lists abnormal operating conditions reported by the LED
displays, points to possible causes, and recommends corrective actions.
Port Usage LEDs
The Port Usage LEDs, labeled 25%50%75%, and
100%, indicate the approximate percentage of B
channels that are being utilized. There are two sets of
Port Usage LEDs, one set for each WAN Port. These
LEDs are normally green. If all available B channels
are in use, they turn amber until at least one call
disconnects.