DSC pc1616 User Manual

Page of 64
5.2 Programming Worksheets
41
[377] Communication Variables
Default 
003
I___
0
__I__
0
__I___
1
__I
Swinger Shutdown (Alarms and Rest)
001-014 Transmissions
003
I___
0
__I__
0
__I___
3
__I
Swinger Shutdown (Tampers and Rest)
001-014 Transmissions, 000=disabled
003
I___
0
__I__
0
__I___
3
__I
Swinger Shutdown (Maint and Rest)
001-014 Transmissions, 000=disabled
000
I___
0
__I__
3
__I___
0
__I
Communication Delay
001-255 seconds
030
I___
0
__I__
3
__I___
0
__I
AC Failure Communication Delay
001-255 minutes
010
I___
0
__I__
1
__I___
0
__I
TLM Trouble Delay 
No. of checks required - valid entries 003 - 255)
030
I___
0
__I__
3
__I___
0
__I
Test Transmission Cycle (land line)
001-255 days/minutes†
030
I___
0
__I__
3
__I___
0
__I
For Future Use
007
I___
0
__I__
0
__I___
7
__I
Zone Low Battery Transmission Delay
000-255 days
030
I___
0
__I__
3
__I___
0
__I
Delinquency Transmission Cycle 
000-255 days/hours
000
I___
0
__I__
0
__I___
5
__I
Communications Cancelled Window
000-255 minutes
†Dependent on programming in section [702], option [3]. 
 For UL installations, the Entry Delay plus Communication Delay time must not exceed 60 seconds.
 To disable the AC failure communications delay, program [000]. 
[378] Test Transmission Time of Day 
Default
[380] First Communicator Options
[381] Second Communicator Options
  9999      
I_______I_______I_______I_______I
 Valid entries are 0000-2359 (9999 to disable)
Opt
Def
ON
OFF
1
9 R
Communications Enabled
R
Communications Disabled
2
R
Restorals on Bell Time-out
9 R
Restorals Follow Zones
3
R
Pulse Dialing
9 R
DTMF Dialing
4
R
Switch to Pulse Dialing on 5th Attempt
9 R
DTMF Dial For All Attempts
5
R
3rd Telephone Number Enabled
9 R
3rd Telephone Number Disabled
6
R
Alternate Dial (1st & 3rd)
9 R
Call 1st Number, Back up to 3rd
7
R
For Future Use
9 R
8
R
Delinquency Follows Zone Activity (Hours)
9 R
Delinquency Follows Arming (Days)
Opt
Def
ON
OFF
1
R
Open After Alarm Keypad Ringback Enabled
9 R
Open After Alarm Keypad Ringback Disabled
2
R
Open After Alarm Bell Ringback Enabled
9 R
Open After Alarm Bell Ringback Disabled
3
R
SIA Sends Programmed Reporting Codes
9 R
SIA Sends Automatic Reporting Codes
4
R
Closing Confirmation Enabled
9 R
Closing Confirmation Disabled
5
9 R
Talk/Listen on Phone Lines 1/3
R
No Talk/Listen on Phone Lines 1/3
6
9 R
Talk/Listen on Phone Line 2
R
No Talk/Listen on Phone Line 2
7
R
Contact ID Uses Programmed Reporting Codes
9 R
Contact ID Uses Automatic Reporting Codes
8
R
For Future Use
9
R