Fostex PD4 Software V2.41 – updated by Sandy MacRae 15:10:03 
No.  Name 
Function 
Display 
Opt
Description 
00* Version off 
01 
Main CPU version 
02 Main 
CPU 
date 
03 
Front CPU version 
001 VER 
Display ROM / CPU Version 
00 1V Er 00 
04 
Transport mechanism version 
00 30 
seconds 
01 1 
minute 
02 2 
minutes 
03* 3 minutes 
04 4 
minutes 
05 5 
minutes 
06 10 
minutes 
104 PCT 
Pause Key Cancel Time Select 
10 4P cT 03 
07 20 
minutes 
00* AES/EBU output format 
105 DOF 
Digital Output Format Select 
10 5d of 00 
01 
S/P DIF output format 
00* AUTO  ID OFF 
01 
ON: S-ID is recorded when RECORD key is pressed 
106 AID 
Auto S-ID / P-No. Recording 
10 6A id 00 
02 
ON: S-ID is recorded when detecting a SIGNAL 
00 All 
OFF 
01* ON: Battery error, Tape low, Peak over, BER error, Ext. TC off
110 ETN 
Error Tone Output Select 
11 0e Tn 01 
02 
ON: Battery error, Tape low only 
00 -  Minimum contrast level  
111 LCD 
LCD Contrast Select 
11 1L Cd 07 
07* Maximum contrast level 
00 OFF 
01 1 
second 
02 2 
seconds 
03* 3 seconds 
04 4 
seconds 
05 5 
seconds 
06 6 
seconds 
07 7 
seconds 
08 8 
seconds 
112 PHT 
Level Meter Peak Hold Time 
11 2P H7 03 
09 9 
seconds 
00* PAUSE function only 
113 PSM 
Pause Key Mode Select 
11 3P SM 00 
01 
Alternates between PAUSE and STOP 
00* Functions only when MIC is selected 
114 LIM 
Limiter Switch Function Select 
11 4L 1M 00 
01 
Functions for both MIC and LINE 
00* Mute function OFF 
116 RMM 
Record Monitor Speaker Mute Select
11 6r MM 00 
01 
Mute function ON 
00 1% 
01* 3% 
117 PEL 
PCM Error LED Level Select 
11 7P EL 01 
02 5% 
00* OFF (Analogue Line Out does not follow Monitor Switch) 
118 LMS 
Line Out Monitor Switch Select 
11 8L MS 00 
01 
ON (Analogue Line Out follows Monitor Switch) 
00 10.0 
01* 10.5 V (NiCad) 
02 11.0 
03 11.5 
04 12.0 
05 
12.5 V (Lithium Ion) 
119 BAL 
Battery Alarm Voltage Level 
11 9b aL 01 
06 13.0 
00 -20 
dB 
01 -30 
dB 
02* -40 dB 
201 AIL 
Auto ID Record Level Select 
(Function 106 set to AUTO 02) 
20 1A iL 02 
03 -55 
dB 
00 300 
ms 
01 600 
ms 
02* 900 ms 
03 1.2 
202 AIT 
Auto ID Record Time Select 
(Function 106 set to AUTO 02) 
20 2A i7 02 
04 1.5 
00* Playback Frame Rate at the RECORDED Frame Rate 
401 TCF 
Playback TC Frame Rate Select 
40 17 CF 00 
01 
Playback Frame Rate set by FRAME RATE switch 
00* Timecode is not output in PAUSE 
403 STC 
Still TC Output Select 
40 3S 7C 00 
01 
Timecode will be output in PAUSE 
00* Automatically switch to GENERATOR 
408 TCO 
TC Output Select in PAUSE or STOP 
40 87 Co 00 
01 
Source remains the TAPE 
00* Roll/YY/MM/DD 
01 DD/MM/YY/Roll 
02 MM/DD/YY/Roll 
03 Event 
No./Roll 
04 User 
Definable 
411 UBD 
User Bit Order Display 
41 1v db 00 
05 YY/MM/DD/Roll 
00* TC and User Bits are jammed 
01 
TC ONLY is Jammed - User Bits remain as PD-4 
412 JAM 
JAM Key Function Select 
41 2J AM 00 
02 
User Bits ONLY are jammed - TC remains as PD-4 
801 MRS 
Memory Reset 
80 1M rS 00 
00 
Reset all functions to DEFAULT Values 
 
* Default Setting
                     