General Troubleshooting  
 
 
 
Symptom 
Possible Cause 
Possible Action 
 
Circuit breaker 
or fuse keeps 
blowing 
·  Excessive load on the circuit  ·  Make sure that the total load 
does not exceed 80% of the 
breaker or fuse nominal 
current 
 
·  Short circuit along the 
power lines 
·  Check the power lines and 
power cords 
 
Product does not 
power up 
·  No energy on power outlet 
·  Check power outlet 
·  Change to another outlet 
 
·  Loose or damaged power 
cord 
·  Check the power cord 
 
·  Blown fuse 
·  Replace blown fuse with a 
good one of the same type 
and rating 
 
·  Internal problem 
·  Send product for repair 
 
Fixture does not 
respond to DMX 
·  Wrong starting address on 
the fixture 
·  Set the correct starting 
address on the fixture 
·  Use the right fader(s) on the 
controller 
 
·  Wrong DMX personality on 
the fixture 
·  Set the correct DMX 
fixture’s personality  
·  Assign the faders 
accordingly 
 
·  Wrong polarity setting on 
the DMX controller 
·  Change the signal polarity 
on the controller 
 
·  Loose or damaged DMX 
cable 
·  Check the DMX cable 
before the faulty unit 
 
·  Internal problem 
·  Send product for repair 
 
Intermittent DMX 
Problems 
·  Signal cables are not DMX 
compatible 
·  Replace non DMX cables 
with true DMX cables 
 
·  Interference with AC or 
radio signals 
·  Keep DMX cables away 
from AC wires or radio 
equipment 
 
·  DMX cable too long 
·  Install an optically coupled 
DMX amplifier right before 
the fixture with intermittent 
problems 
 
·  Too many fixtures 
connected 
·  Install an optically coupled 
DMX amplifier after unit #32 
 
·  Terminator not connected 
·  Install a terminator, as 
indicated in the “DMX 
Primer” section. 
 
 
 
If you still experience problems after trying the above solutions, contact 
CHAUVET® Technical Support.