Report No.: RM920221R04A
17
Issued: Mar. 14, 2003
Reference No.: RM920221R04
5.4.3 TEST PROCEDURE
   
a.  Electrostatic discharges were applied only to those points and surfaces of the
EUT that are accessible to users during normal operation.
b.  The test was performed with at least ten single discharges on the pre-selected
points in the most sensitive polarity.
c.  The time interval between two successive single discharges was at least 1
second.
d.  The ESD generator was held perpendicularly to the surface to which the
discharge was applied and the return cable was at least 0.2 meters from the
EUT.
e.  Contact discharges were applied to the non-insulating coating, with the pointed
tip of the generator penetrating the coating and contacting the conducting
substrate.
f.  Air discharges were applied with the round discharge tip of the discharge
electrode approaching the EUT as fast as possible (without causing
mechanical damage) to touch the EUT. After each discharge, the ESD
generator was removed from the EUT and re-triggered for a new single
discharge. The test was repeated until all discharges were complete.
g.  At least ten single discharges (in the most sensitive polarity) were applied to
the Horizontal Coupling Plane at points on each side of the EUT. The ESD
generator was positioned vertically at a distance of 0.1 meters from the EUT
with the discharge electrode touching the HCP.
h.  At least ten single discharges (in the most sensitive polarity) were applied to
the center of one vertical edge of the Vertical Coupling Plane in sufficiently
different positions that the four faces of the EUT were completely illuminated.
The VCP (dimensions 0.5m x 0.5m) was placed vertically to and 0.1 meters
from the EUT.
5.4.4  DEVIATION FROM TEST STANDARD
No deviation