Belkin f5d7000ce2 User Manual

Page of 29
Report No.: RM920221R04A
21
Issued: Mar. 14, 2003
Reference No.: RM920221R04
5.5  RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY
TEST (RS)
5.5.1 TEST SPECIFICATION
Basic Standard: EN 61000-4-3
Frequency Range: 80 MHz - 1000 / 1400 - 2000 MHz
Field Strength: 3 Vrms
Modulation: 1kHz Sine Wave, 80%, AM Modulation
Frequency Step: 1 % of momentary frequency
Polarity of Antenna: Horizontal and Vertical
Test Distance: 3 m
Antenna Height: 1.5m
Dwell Time: at least 3 seconds
5.5.2 TEST INSTRUMENT
DESCRIPTION & MANUFACTURER
MODEL NO.
SERIAL NO.
CALIBRATED
UNTIL
ROHDE & SCHWARZ Signal Generator
SMY01
840490/009
July 31, 2003
KALMUS Power Amplifier
LA1000V
091995-1
NA
KALMUS Power Amplifier
757LC
091995-2
NA
HOLADAY Field Probe
HI-4422
89915
Mar. 05, 2003
EMCO BiconiLog Antenna
3141
1001
NA
COMTEST Compact Full Anechoic
Chamber (7x3x3 m)
CFAC
ADT-S01
Aug. 10, 2003
HP Signal Generator
E4422A
US37040138
Jun. 10,2003
AR RF Amplifier
80S1G3
304334
NA
W&G E-Field Sensor 3GHz
TYP-8
AD-0034
Dec. 22, 2003
W&G EM Radiation Monitor
EMR-20
AB-0039
Dec. 22, 2003
R&S Power Sensor
NRV-Z5
837878/038
Nov. 20, 2003
R&S Power Sensor
NRV-Z5
837878/039
Nov. 20, 2003
R&S Power Meter
NRVD
837794/040
Nov. 20, 2003
NOTE: 1. The test was performed in RS Room.
2. The calibration interval of the above test instruments is 12 months and the
    calibrations are traceable to NML/ROC and NIST/USA.