Contec SPI-8451-LLVA User Manual

Page of 123
6. RAID Controller 
 
 
 
58 
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA 
Viewing Arrayed Drive Information 
By left-clicking on a drive member of an array in the left pane, the right pane shows the following 
information categories for that drive: 
 
 Status: 
(also shown under the Array Window) can be Functional, Critical, or Offline. The meanings 
are shown below. 
 Functional: 
Means the drive is working normally. 
 Critical: 
problem has been detected in the drive and the drive taken offline as part of a mirroring 
array. Mirrored arrays will continue to function without the drive. Fix/replace the drive that has failed, 
and then restore data from a backup source. 
 Offline: 
Drives that are NOT identified as “bad” may be taken offline if part of a Striping or 
spanning array containing a “bad” drive. These drives do NOT need to be replaced, however. 
 S.M.A.R.T. 
Status: 
Indicates whether attached hard drive implements Self-Monitoring analysis & 
Reporting Technology to predict drive failure 
 Size: 
Indicates capacity of individual drive 
 Location: 
Shows physical location of drive. Indicates on which IDE channel (1 or 2), and whether 
drive is Master or Slave on cable. This allows user to identify drives for removal/replacement. 
 Mapping: 
Indicates physical parameters of drive (cylinders, heads, sectors) 
 Timing: 
Shows selection of drive timing (directly related to burst speed) based on type of drive and 
cable used.