Chauvet intimidator dmx-605a User Manual

Page of 15
 
DMX-605A & DMX-610A User Manual 
2005-11-16/16:16
 
Optional Controller 
Daisy Chain 
Connection 
O
PERATING 
I
NSTRUCTIONS
 
Operating Modes 
 
 
A stand-alone mode will listen to sound and run through its diverse range of built in programs.  
 
Master/Slave mode will allow the command of up to as many units you want in a synchronized light show to the 
sound. 
 
DMX control mode will provide the greatest flexibility and creativity. Each fixture trait can be controlled individually 
using any universal DMX-512 controller.  
Stand Alone 
The Stand Alone mode is activated automatically when the fixture is absent of DMX signal or a 
controller is not connected. The fixture will run through its built in programs as it listens to the sound. 
Master/Slave 
The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In 
this mode, the first unit in the daisy chain will automatically command all other units following. 
Connecting this fixture for (Master/Slave) operation does not require any menu or setting selections. 
Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below.  
M AST E R / S L AV E   S ET T I N G S 
1) 
Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector 
of the first fixture.  
2) 
Connect the end of the cable coming from the first fixture which will have a (female) 3 pin 
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, 
proceed to connect from the output as stated above to the input of the following fixture and so on 
as illustrated below.  
Note!  
For additional information on linking fixtures read under section 
DMX Primer
 
DMX Mode 
Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to 
customizing or creating a show.  In this mode you will be able to control each individual trait of the 
fixture independently.  
S ET T I N G   T H E  ST AR T I N G   AD D R E SS 
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start 
address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data 
on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels 
of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 
102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate 
the start address selected for future reference.