A.2
In the Case Where RCI Status of RCI Host 
Changes From ACTIVE to INACTIVE
Remarks:  When this problem has occurred, do not replace the XSCF unit because it 
is not a failure of the XSCF unit.
This problem is occurred by the mistake of the RCI construction procedure and the 
RCI connection.
t occurrs when the same RCI address is set and constructed, or, when connecting with 
the RCI network of the construction of the RCI host that has not been initialized.
Confirm whether to correspond to this problem.  The procedure is the following: 
1 Excute showlogs command, and check whether RCI configuration conflict is 
generated in error log.
2 When that message was generated, check the RCI establishment procedure, 
the RCI address value and the connection.
3 In the case of anomaly, correct the RCI address or the connection of relevant 
device according to the change procedure of each device.
4 Refer to 
 and retry RCI 
establishment.