Desa VM36(B,H) User Manual

Page of 32
www.desatech.com
108795-01V
5
The installation must conform with local codes 
or, in the absence of local codes, with the cur-
rent National Fuel Gas Code, ANSI Z223.1/
NFPA 54
. This appliance complies with ANSI 
Z21.50/CSA 2.22
.
  WARNING:  Installation  of 
this appliance should be done
by  a  qualified  service  person
well  trained  in  the  installation
of  such  appliances.  You  will
also need a building permit from
your local Building and Safety 
Commissioner before installing
this  appliance;  otherwise  your
insurance co. may not cover this
appliance.
NOTICE:  This  appliance  is  not 
intended to be used as a primary
source of heat.
INtroduCtIoN
Continued
Figure 1 - Possible Locations for 
Installing Appliance 
INTERNAL WALL
INSTALLATION
CORNER
INSTALLATION
FULL
PROJECTION
INSTALLATION
FLUSH
INSTALLATION
  CAUTION:  Do  not  connect 
appliance before pressure test-
ing gas piping. Damage to gas
valve may result and an unsafe 
condition may be caused.
The appliance and it’s individual shutoff valve 
must be disconnected from gas supply piping 
system  during  any  pressure  testing  of  that 
system  at  test  pressures  in  excess  of  1/2 
psig (3.5 kPa).
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shutoff valve during any pressure testing 
of the gas supply piping system at test pressures 
equal to or less than 1/2 psig (3.5 kPa).
For  the  purpose  of  input  adjustment  two 
pressure  taps  (for  IN  and  OUT  pressures) 
are provided on the gas control valve for test 
gauge connections to the appliance.
Flush installations are recommended where 
living  space  is  limited  or  at  a  premium  and 
since the space required to enclose the ap-
pliance would be located beyond an outside 
wall,  this  would  also  reduce  the  cutting  of 
joists,  roof  rafters  and  such.  Check  local 
codes for any restrictions.
Projected  installations  can  extend  any 
distance  into  the  room. A  projection  may 
be  ideal  for  a  new  addition  on  an  existing, 
finished wall.
Corner  installations  make  use  of  space 
that may not normally be used and provides 
a wider and more efficient range for radiant 
heat transference.
Internal wall installations provide a discreet 
option for room separation and can also be 
ideal as an addition to an existing wall.
seleCtING loCatIoN
To  determine  the  safest  and  most  efficient 
location for your appliance, you must take into 
consideration the following guidelines:
1.  The location must allow for proper clear-
ances (see Clearances, page 7).
2.  Consider  a  location  where  heat  output 
would not be affected by drafts, air con-
ditioning ducts, windows or doors.
3.  A location that avoids the cutting of joists 
or roof rafters will make installation easier. 
Figure 1 shows a plan view of a few com-
mon locations.