CMA Dishmachines CMA-180UC User Manual

Page of 25
 
2.2.6.  Booster Heater Setup 
The booster tank must be filled with water before the heating element is energized.  
For this reason the “High Limit Switch” has intentionally been activated at the factory 
and will require resetting before the heating element will turn on. 
Follow the procedure below to complete the initial installation: 
1.  Close the door on the machine. 
2.  Turn the Power switch to the "ON" position. 
3.  Hold the “FILL” switch in until water overflows into the scrap tray. 
4.  Turn the Power switch to the "OFF" position. 
5.  Connect blue wire with disconnect, identified by red tag, to the High Limit 
Switch which is located behind the thermostat behind the front kick panel.   
2.2.7. Installers 
Checklist 
 
Dishmachine checked for concealed damage 
 
Hot water supply is 140° F (60 C) — minimum 
 
Incoming water supply line is ½” — minimum 
 
Incoming water supply is 6 GPM minimum at 24 PSI 
 
Supply circuit breaker for machine is properly sized (50 amp) 
 
Service voltage and phase type are correct to machine data plate 
 
If drain pump is used, drain hose rises 12 to 16” before dropping to drain 
 
Drain hose is installed with air gap (discharge 1” above drain) 
 
Optional detergent and rinse dispenser (if present) is properly installed 
 
Dishmachine is properly grounded 
 
Dishmachine is properly leveled 
 
Machine circuit breaker is labeled  “DISHWASHER” 
 
Machine has been “hard-wired” with correctly sized wire 
 
Booster tank has been filled with water (before High Limit Switch is reset) 
 
High Limit Switch for heater has been reset (after Booster Tank has been filled) 
 
MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15 