Installation Instructions
3.  Connect the hood wiring to an electrical junction box on a dedicated circuit. See page 4 for specifications. Connect 
it according to one of the wiring diagrams below.
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
3 wire connection to Junction Box
To house circuit breaker 
panel or fuse box
Junction 
box
Wire nut, 
3 places
 wArning
•  Do not ground the circuit to a gas line or hot water 
pipe.
•  Water lines that are insulated must be jumped to 
assure continuity to ground. See below.
insulated pipe Jumper
(if necessary)
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
grounding the hood wiring using 
an external cold water pipe
UL/CSA approved 
NEMA strain relief
UL/CSA approved 
NEMA strain relief
Fasten clamp 
tightly on pipe
Separate No. 10 (minimum) 
copper ground wire
To house circuit breaker 
panel or fuse box
To range 
hood
To range 
hood
Wire nut, 
3 places
Junction 
box
Meter
Clamps
Bare metal
No. 4 copper 
wire