Fujitsu image scanner fi-5950 User Manual

Page of 26
AP-4
Appendix 2
DAILY CARE
■ Cleaning Materials
*1: For details about the cleaning materials, contact the 
FUJITSU scanner dealer where you purchased the 
scanner.
*2: Pre-moistened with Cleaner F1, Cleaning Wipes are 
used instead of moistened cloths.
■ Cleaning Method
The ADF and the Feed rollers must be cleaned with a 
lint-free cloth moistened with the Cleaner F1.
■ Locations and Cycle for Cleaning
For details on the cleaning the ADF, refer to "4.DAILY 
CARE" in the fi-5950 Operator’s Guide on the SETUP 
DVD-ROM".
CAUTION
   
During its operation, the inside 
glass of the ADF becomes very hot.
Before you clean inside the scan-
ner, turn off its power and unplug 
the AC adapter from the outlet. Wait 
for at least 15 minutes.
Do not turn off the scanner when 
you clean the Feed rollers or Eject 
rollers.
Cleaning 
Materials
Parts No.
Remarks
Cleaning sheet
CA99501-
0016
20 sheets/pack
For the cleaning method, 
refer to "4 DAIRY 
CARE in the fi-5950 
Operator’s Guide.
Cleaner F1
PA03950-
0352
1 bottle
Moisten a cloth with this 
fluid and wipe the scan-
ner to clean.
Cleaning wipe
PA03950-
0419
24 sheets per pack
(*1)(*2)
Cotton swab
Commercially available
Lint-free dry 
cloth
ATTENTION
It may take long before the cleaner 
vaporizes if a large quantity is used. 
When cleaning the scanner parts, 
dampen a cloth with modest quantities 
of the cleaner. In addition, wipe off the 
cleaner completely with a soft lint-free 
cloth to leave no residue on the surface 
of the cleaned parts. 
Part to clean
Standard Cleaning Cycle
Pad
Clean these parts after every 
10,000 scans.
Pick rollers
Brake roller
Separator rollers
Feed rollers
Pinch rollers
Transport path
Glass
Skew-detection sensor
Document sensor
ATTENTION
The scanner must be cleaned more fre-
quently if you scan any of the following 
type of sheets:
Documents of coated paper
Documents that are almost completely 
covered with printed text or graphics
Chemically treated documents such 
as carbonless paper
Documents containing a large amount 
of calcium carbonate
Documents written with pencil
Documents on which the toner is not 
sufficiently fused