Fujitsu M3097G User Manual

Page of 163
D.1
Enhanced Functions and Functional Differences
This section explains the functions added to M3096G image scanners and the
functional differences between M3096G and M3097G image scanners.  This is
useful when installing M3097G image scanners.
Table D.1.1 lists the added functions.
Table D.1.1 Added functions
No.
Function added
Section to be
referenced
Remarks
1
The paper size detection function is added for an
automatic document feeder (ADF).  The applicable paper
sizes are A3 or double>letter (DL), A4 or letter (LT), A5,
B4, and B5.
D.1.1.1
Added
2
The job separation sheet detection function is added.
D.1.1.2
Added
3
Error diffusion is added to halftone processing.
D.1.1.3
Added
4
The contrast control function is added.
D.1.1.4
Added
5
Gamma correction is added.
D.1.1.5
Added
6
Dynamic threshold (equivalent to M3094A11) is enabled
by the IPC II option (M3097E0191).
D.1.1.6
Added
7
The function for designating the period between lit>on
and lit>off times on the fluorescent lamp is added.
D.1.1.7
Added
8
The sense code for a blown lamp fuse, and interlock
switch open are added.
D.1.1.8
Added
Table D.1.2 lists the functional differences between two models.
Table D.1.2 Functional differences
No.
Differences
M3097G
M3096G
1
The required image data transmission speed is faster
because the reading speed of the M3097G is twice that
of the M3096G.
More than
1.3 MB/s
More than
625 KB/s
2
After turning on the scanner, the period between ™Not
ready∫ and ™Ready∫ becomes longer.
25∞C, 60s
 5∞C,  5min.
25∞C, 30s
 5∞C,  3min.
3
Gray scale output
Not
supported
Supported
D $ 2