bk avr212 User Manual

Page of 88
 
67
Set the Zone ID for Zone B - Each message transmitted from your remote includes a Product ID Code Set (See 
Zone ID), which allows independent command and control of the receiver’s Zones A and B. Set the desired zone 
ID number for use with Zone B (default 2). You may not set the Zone B zone ID to the same setting as Zone A 
(default 1) or vice versa. If you need to set Zone B to the current Zone A setting then you must first set Zone A to 
some other Zone ID value. 
 
WARNING - if you change the Zone product ID code set in the receiver without making the corresponding 
change to the remote then the remote will no longer appear to work. Refer to the separate remote manual 
for details on changing the remote’s product ID code set (“device code”). 
 
 
 
From Remote 
From Front Panel 
Action 
À(PAUSE) or §(STOP) 
(UP) or (DOWN) 
move to Zone ID 
(REW) or
 •
(FF) 
VOLUME KNOB 
adjust Zone 2 (B) ID to desired value 
 
Set V2 line output usage -
 V2 output is normally set up as a tape loop. The V2 and Zone 2 (B) output are the 
current source (V1, TV, CD, DVD, etc.) except when the current selection is V2. When V2 is selected as the 
source, the Zone 2 (B) output is V2 and the V2 output is the previously selected source. This prevents feedback 
when the V2 inputs and outputs are connected to a tape deck or VCR. Feedback can cause high frequency 
oscillations, which may damage your speakers. If you don’t connect a tape deck to the V2 input and output you 
can use the V2 output as an additional line out. In this mode V2 output is always the selected input including V2. 
 
 
From Remote 
From Front Panel 
Action 
À(PAUSE) or §(STOP) 
(UP) or (DOWN) 
move to V2 Output 
(REW) or
 •
(FF) 
VOLUME KNOB 
set for Tape or Line 
 
  ADVANCED ZONE B SETTINGS
1  Level Control              Variable
2  Maximum Level           +15 dB
3  Zone ID                             2
4  V2 Output                       Tape
5  Link Input  to Zone A        No
6  Link Power to Zone A       No
     next item              adjust
         MENU advanced setup
3  Zone ID                             2
ZB ZONE ID    2
  ADVANCED ZONE B SETTINGS
1  Level Control              Variable
2  Maximum Level           +15 dB
3  Zone ID                             2
4  V2 Output                       Tape
5  Link Input  to Zone A        No
6  Link Power to Zone A       No
     next item              adjust
         MENU advanced setup
4  V2 Output                       Tape
ZB V2 OUT   TAPE
  ADVANCED ZONE B SETTINGS
1  Level Control                Fixed
2  Fixed Level                  +15 dB
3  Zone ID                             2
4  V2 Output                       Line
5  Link Input  to Zone A        No
WARNING Connecting a tape
 recorder to V2 in LINE mode
 can cause speaker damage
     next item              adjust
         MENU advanced setup
4  V2 Output                       Line
ZB V2 OUT   LINE