fetco cbs-2032e User Manual

Page of 24
 
12 
Error Codes 
Code 
Description 
Possible Cause 
Corrective Action 
How to Clear Error 
Codes 
001 Internal 
Error 
System had to reload default 
settings. 
Control board failure. 
Clear error. 
Re-program the brewer to the 
desired specifications. If error 
occurs again, replace control 
board. 
Turn main power 
switch off and on. 
050 
Shorted temperature probe. 
Probe failure. 
Replace probe. 
Turn main power 
switch off and on. 
051 
Open temperature probe. 
Bad probe connection, or 
probe failure. 
Check all connections. Replace 
probe if necessary. 
Turn main power 
switch off and on. 
075 
or 
NO 
BAS 
CBS-2031e / 2032e 
Brew Basket Sensor 
 
These models do not 
have brew basket 
sensors or locks. This 
error indicates a bad 
connection on the brown 
jumper wire on the Molex 
connector connected to 
the top of the control 
board. 
Press both ends of the jumper 
wire into the connector to make 
better contact. 
 
Brew basket sensor or 
lock has failed. 
If the brew basket can be 
pulled out during the 
brew cycle, the brew 
basket lock has failed. 
Repair or replace brew basket 
sensor or lock. 
Press the flashing 
control panel power 
switch to resume 
operation. 
075 
CBS-2031s / 2032s 
Brew basket lock or sensor 
failure. 
 
Magnet in brew basket 
handle is missing or 
loose. 
Remove brew basket handle. 
Place magnet in correct 
position. 
 
100 
Initial Fill Error 
Initial fill time was more than 
15 minutes. 
Water supply flow rate is 
too low. 
Watch for short potting during 
brew cycle. Investigate cause of 
low flow rate. (Clogged water 
filter, etc.) 
Press the control 
panel power switch. 
101 
Error on refill 
Tank did not refill within 3 
minutes. 
Water supply flow rate is 
too low. 
Watch for short potting during 
brew cycle. Investigate cause of 
low flow rate. (Clogged water 
filter, etc.) 
Error message is 
cleared automatically 
at end of brew cycle. 
Possible leak in tank, 
fitting, or valve. 
Check inside of machine for 
leaks. 
102 Unwanted 
Fill 
When brewer is idle, the fill 
valve was activated for more 
than 30 seconds during a 1 
hour period. 
Output on control board 
has failed, causing a 
dispense valve to open. 
Replace control board. 
Turn main power 
switch off and on. 
200 
Flat Line Temperature 
(Water is boiling) 
System is calling for heat, but 
the temperature does not rise 
at least 2
°F  within 10 minutes. 
Triac is stuck closed, bad 
output on control board, 
or temperature is set too 
high for altitude. 
Check triacs, check control 
board output, or adjust 
temperature for altitude. 
Turn main power 
switch off and on. 
201 Heater 
Open 
System is calling for heat, but 
the temperature does not rise 
at least 2
°F  within 10 minutes. 
This error is disabled during 
brewing and while using the 
hot water faucet. 
Heating element failure. 
Check and replace heating 
elements if necessary. 
Turn main power 
switch off and on. 
202 Heater 
Short 
System is not calling for heat, 
but temperature rises more 
than 5
°F. 
Possible triac stuck 
closed, or bad output on 
control board. 
Check triac and control board. 
Enter programming 
mode, then exit 
programming mode. 
255 Keypad 
Error 
A switch was pressed for more 
than 45 seconds. 
Switch was held in too 
long, or switch is stuck 
closed. 
Clear error and try again. If 
error occurs without switch 
being pressed, replace input 
board. 
Turn main power 