Fluke 1744 User Manual

Page of 73
 
Power Quality Logger 
 Technical 
Specifications 
 
  
55 
Logging Function A – “All” parameters 
Logging Values 
All parameters for voltage quality per EN 50160: 
Voltage L1 or A, L2 or B, L3 or C: phase-phase or phase-neutral: 
  Voltage (mean, max, min values) 
  Voltage harmonics 1
st
 to 50
th
 order 
  THDV (harmonic contents of voltage) 
  Interharmonics 5 to 2500 Hz (in steps of 0.5 Hz) 
  Flicker Pst,Plt 
  Unbalance 
  Signaling voltages 
  Frequency 
  Voltage events (dips, swells, interruptions) 
Current L1 or A, L2 or B, L3 or C, and N: 
  Current (mean, max values) 
  Harmonics of phase and neutral currents up to 50
th
 order 
  Crest factor and peak values of the currents 
Power: 
  Active power P (mean, min, and max values) 
  Absolute values active power |P| (mean, min, and max values) 
  Distorting power D (mean, min, and max values) 
  Apparent power S (mean, min, and max values) 
  Power Factor PF, tangent 
  Energy per averaging interval