The back panel consists of the power switch, AC adapter connector, charging
indicator, IR port, RS-232 port connector, IEEE-488 port connector (optional),
serial label, and probe connectors. The 1529 thermometer readout can be con-
figured in three different ways. The configuration affects the probe connectors
on the back panel. The Model 1529 is configured with one PRT/thermistor in-
put module of two channels and one thermocouple input module of two chan-
nels. The Model 1529-R is configured with two PRT/thermistor input modules
of four channels. The Model 1529-T is configured with two thermocouple input
modules of four channels. Figure 3 shows the back panel and the three different
configurations.
indicator, IR port, RS-232 port connector, IEEE-488 port connector (optional),
serial label, and probe connectors. The 1529 thermometer readout can be con-
figured in three different ways. The configuration affects the probe connectors
on the back panel. The Model 1529 is configured with one PRT/thermistor in-
put module of two channels and one thermocouple input module of two chan-
nels. The Model 1529-R is configured with two PRT/thermistor input modules
of four channels. The Model 1529-T is configured with two thermocouple input
modules of four channels. Figure 3 shows the back panel and the three different
configurations.
Power Switch - The power switch turns the thermometer readout on and off.
AC Adapter Connecor - The AC adapter plugs into the DC power input to re-
charge the battery and to power the instrument while the battery is being
charged (see Section 6.3, Battery).
charge the battery and to power the instrument while the battery is being
charged (see Section 6.3, Battery).
Charging Indicator - The charging indicator lights when the AC adapter is
connected. It glows green when the battery is at full charge and amber when the
battery is being charged.
connected. It glows green when the battery is at full charge and amber when the
battery is being charged.
IR Port-The infrared window provides a means for downloading the 1529
logged data. The infrared window can be used in any of the following ways.
logged data. The infrared window can be used in any of the following ways.
• with an I/R dongle and the 9935 LogWare Software
• with a Hart Scientific 2385 printer
• with an IrDA compatible printer
• with a Hart Scientific 2385 printer
• with an IrDA compatible printer
RS-232 Port Connector - The DB-9 connector is for interfacing the thermom-
eter readout to a computer or terminal with serial RS-232 communications.
eter readout to a computer or terminal with serial RS-232 communications.
IEEE-488 Port (optional) - The GPIB connector is for interfacing the ther-
mometer readout to a computer or terminal with IEEE-488 communications.
mometer readout to a computer or terminal with IEEE-488 communications.
Serial Label - The serial label shows the instrument model and serial number.
Probe Connectors - Probe(s) must be connected either to the patented
mini-DWF connectors (PRT/thermistor probes) or to the universal receptacle
(thermocouples) for operation.
mini-DWF connectors (PRT/thermistor probes) or to the universal receptacle
(thermocouples) for operation.
5.3
Accessories
The 1529 thermometer readout comes standard with a hand strap on the side
for easy carrying of the instrument. The following accessories are also
available:
for easy carrying of the instrument. The following accessories are also
available:
• 2513-1529 Rack Mount Kit
• 9323 Soft Carrying Case
• 9322 Hard Carrying Case
• 9323 Soft Carrying Case
• 9322 Hard Carrying Case
19
5 Parts and Controls
Back Panel