Garmin gpsmap 168 User Manual

Page of 118
39
Reference
Sonar Tab Options
•    Scale— controls the depth ‘Scale’ displayed vertically along the right side of the chart. The 
depth ‘Scale’ can be confi gured to display four different ways: as an ‘Overlay’, in the ‘Corners’, 
with ‘Basic’ or ‘No Scale’.  
•    Noise Reject— helps fi lter unwanted noise from the chart. The ‘Noise Reject’ tool can be 
turned ‘Off’, set to ‘Auto’ (automatically adjusts for optimum viewing) or to a fi xed ‘Low’, 
‘Medium’ or ‘High’ setting. 
When setting the Noise Reject tool:  the HIGHER the noise rejection setting, the unit is 
more likely to NOT show fi sh or structure.
•    Keel Offset— allows the user to offset the surface reading for the depth of a keel. This makes 
it possible to measure depth from the bottom of your keel instead of from the transducer’s 
location. Enter a positive number to offset for a keel. It is also possible to enter a negative 
number to compensate for a large vessel that may draw several feet of water. The ‘Keel Offset’ 
will be refl ected in the depth reading.
•    Water Type— since sound waves travel through ‘Fresh’ and ‘Salt’ water at different rates it is 
necessary to select the ‘Water Type’ to ensure accurate readings on the unit. 
•    Remember— the unit can be set to remember ‘All’ of the Sonar settings including the 
Adjustment Bar (even after it has been powered off and back on), or just the ‘Setup Only’ 
items on the Sonar tab. 
•    Calibrate Water Speed— this is only available if you are using a speed-capable transducer. 
Calibration is required to ensure that the Water Speed displayed on your unit will be accurate. 
The unit will automatically use the GPS ground speed, if it is available, for comparison on 
the calibration. If a GPS ground speed is not available, use either your boat’s speedometer 
reading (not always accurate) or a stopwatch to determine your speed over a certain distance 
(distance / time = speed). It is recommended that the calibration take place in water having 
little or no current.
F
Calibrating the Speed Sensor
Transducer at Surface
Enter (+) positive 
number to show depth 
from bottom of keel
Transducer at Bottom of Keel
Enter (-) negative number to show 
depth from surface
168 Manual Part 1.indd
01/09/01, 10:41 AM
39