Crestron cnmsx User Manual

Page of 44
Crestron CNMSX 
Integrated Control System
 
As of the date of manufacture, the unit has been tested and found to comply with 
specifications for CE marking. 
 
NOTE:  This device complies with part 15 of the FCC rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and (2) 
this device must accept any interference received, including interference that may cause 
undesired operation.  
Setup 
Rack Mounting 
WARNING:  To prevent bodily injury when mounting or servicing this unit in a 
rack, take special precautions to ensure that the system remains stable.  The following 
guidelines are provided to ensure your safety: 
 The unit should be mounted at the bottom of the rack if it is the only unit in the 
rack. 
 When mounting this unit in a partially filled rack, load the rack from the bottom 
to the top with the heaviest component at the bottom of the rack. 
 If the rack is provided with stabilizing devices, install the stabilizers before 
mounting or servicing the unit in the rack. 
 
NOTE:  If rack mounting is not required, rubber feet are provided for table-top 
mounting or stacking. Apply the feet near the corner edges on the underside of the 
unit.  
NOTE:  Reliable earthing of rack mounted equipment should be maintained.  
Particular attention should be given to supply connections other than direct 
connections to the branch circuit. (e.g., use of power strips). 
Two “ears” are provided with the CNMSX so that the unit can be rack mounted. 
These ears must be installed prior to mounting. Complete the procedure below to 
attach ears to CNMSX. The only tool required is a #2 Phillips screwdriver.  
1.  There are 12 screws (#6-32 x 0.375" LG) that secure the sides of the 
CNMSX top cover.  Using a #2 Phillips screwdriver, remove the three 
screws closest to the front panel from one side of the unit.  
2.  Position a rack ear so that its mounting holes align with the holes 
vacated by the screws in step 1.  
3.  Secure the ear to the CNMSX with three screws from step 1, as shown 
on the next page.  
Operations Guide - DOC. 8118B 
Integrated Control System:  CNMSX  
  11